Owner complaints for the 2001 Nissan Maxima do not stand out strongly from the model-year median of 99.

About this comparison →

When problems were reported

Mileage at the reported incident

117 reports with mileage · 55 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Air Bags. Review the 29 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine And Engine Cooling. Review the 28 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 27 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

8 crash reports4 fire reports6 injury reports

Tires complaints

6 reports
Clear category filter
117,379 miles · Jul 26, 2007
Tires

TL*THE CONTACT OWNS A 2001 NISSAN MAXIMA. THE CONTACT TOOK HIS VEHICLE TO THE DEALER FOR REGULAR MAINTENANCE AND LEARNED THAT HIS FRONT BRIDGESTONE POTENZA, SIZE P225/50R1793V TIRES HAD CRACKS ON THE SIDEWALLS. HE STATED THAT TWO PRIOR SET OF TIRES HAD THE SAME FAILURE. THE CURRENT AND FAILURE MILEAGES WERE 117,379. UPDATED …

Read full complaint

TL*THE CONTACT OWNS A 2001 NISSAN MAXIMA. THE CONTACT TOOK HIS VEHICLE TO THE DEALER FOR REGULAR MAINTENANCE AND LEARNED THAT HIS FRONT BRIDGESTONE POTENZA, SIZE P225/50R1793V TIRES HAD CRACKS ON THE SIDEWALLS. HE STATED THAT TWO PRIOR SET OF TIRES HAD THE SAME FAILURE. THE CURRENT AND FAILURE MILEAGES WERE 117,379. UPDATED 11/06/07 *TR

NHTSA ODI #10197593

Mileage unknown · Nov 21, 2006
Tires

I WANTED TO BRING TO YOU NOTICE THAT, CARX LOCATED AT 7880 TYLERSVILLE SQ DR, WEST CHESTER OH 45069-4688, (513) 777-7945 IS SELLING LOW QUALITY "FEDERAL" BRAND TIRES. NHTSA (NATIONAL HIGHWAY TRAFFIC SAFETY AGENCY) HAS RATED MORE THAN 2,400 LINES OF TIRES AND THE "FEDERAL TIRE" BRAND SOLD BY CARX DOES NOT EVEN APPEAR ON THEIR L…

Read full complaint

I WANTED TO BRING TO YOU NOTICE THAT, CARX LOCATED AT 7880 TYLERSVILLE SQ DR, WEST CHESTER OH 45069-4688, (513) 777-7945 IS SELLING LOW QUALITY "FEDERAL" BRAND TIRES. NHTSA (NATIONAL HIGHWAY TRAFFIC SAFETY AGENCY) HAS RATED MORE THAN 2,400 LINES OF TIRES AND THE "FEDERAL TIRE" BRAND SOLD BY CARX DOES NOT EVEN APPEAR ON THEIR LIST!! CHECK IT OUT FOR YOURSELF AT THIS PAGE (DROP DOWN LIST)HTTP://WWW.SAFERCAR.GOV/TIRES/PAGES/TIRERATINGS.CFM. I AM NOT SURE IF THE "FEDERAL" TIRE COMPLIES WITH NHTSA DEVELOPED TIRE SAFETY GRADING SYSTEM, KNOWN AS THE "UNIFORM TIRE QUALITY GRADING SYSTEM (UTQGS)", THAT ALLOWS CONSUMERS TO COMPARE TIRE TREADWEAR, TRACTION PERFORMANCE, AND TEMPERATURE RESISTANCE. THE FEDERAL GOVERNMENT REQUIRES TIRE MANUFACTURERS TO GRADE THEIR TIRES IN THESE THREE AREAS AND PLACE THE INFORMATION ON THE SIDEWALL OF THE TIRE. CAN YOU PLEASE ADVICE REGARDING A RETAILER SELLING TIRES NOT LISTED IN THE NHTSA DATABASE ?? I AM CONCERNED ABOUT THE SAFETY OF THE TIRES SINCE THESE TIRES ARE NOT LISTED IN NHTSA DATABASE ...... MOREOVER, I DID NOT EVEN FIND THE 'FEDERAL' BRAND TIRES LISTED IN THE TOP 25 (TWENTY FIVE) TIRE BRANDS. THE TIRE PRESSURE IS NOT CONSISTENT AND HAS TO BE FILLED EVERY FEW DAYS ... TOOK THE CAR TO CARX AND THEY DON'T SEEM TO CARE. *NM

NHTSA ODI #10174020

23,000 miles · Aug 18, 2003
Tires

MY CAR IS A 2001 MAXIMA IT CAME WITH TOYO TIRES FROM THE FACTORY. I GOT A FLAT AND WENT TO HAVE IT REPAIRED THEY WOULDNT FIX IT BECAUSE THE TIRE AND THE OTHER TIRES ON THE CAR ARE DRY ROTTED. THE TIRES HAD 23,000 MILES ON THEM AND WERE QUITE WORN NOT WHAT YOU WOULD EXPECT FROM A PREMIUM TIRE. THE LAST TIME THE CAR WAS IN FOR SER…

Read full complaint

MY CAR IS A 2001 MAXIMA IT CAME WITH TOYO TIRES FROM THE FACTORY. I GOT A FLAT AND WENT TO HAVE IT REPAIRED THEY WOULDNT FIX IT BECAUSE THE TIRE AND THE OTHER TIRES ON THE CAR ARE DRY ROTTED. THE TIRES HAD 23,000 MILES ON THEM AND WERE QUITE WORN NOT WHAT YOU WOULD EXPECT FROM A PREMIUM TIRE. THE LAST TIME THE CAR WAS IN FOR SERVICING THE TECH TOLD MY WIFE THAT THEY WOULD NEED TO BE REPLACED IN THE NEAR FUTURE.. I CALLED TOYO AND THEY SENT ME TO THIER DEALER IN NAPLES FLORIDA. THE TECH THERE CONFIRMED THAT THE TIRES WERE IN FACT DEFECTIVE. HE CALLED TOYO WITH THE TREAD DEPTH AND INFORMED THEM OF THE DRY ROTTING. THEY SAID THEY WOULD GIVE ME A ADUSTMENT ON THE TIRES BUT WOULD HAVE TO SEE THEM. WELL IT HAS BEEN TWO MONTHS AND I STILL DONT HAVE THE ADJUSTMENT CHECK. I'M NOT HAPPY ABOUT THAT EITHER ! *AK

NHTSA ODI #10033065

Mileage unknown · Jun 25, 2002
Tires

AFTER PURCHASING A NEW 2001 NISSAN MAXIMA SE IN AUGUST 2001, I TAKEN IT BACK TO THE DEALERSHIP OVER FIVE TIMES BECAUSE OF THE STEERING AND VIBRATION OF THE TIRES AND THE PROBLEM IS STILL NOT FIXED.*AK

NHTSA ODI #763440

Mileage unknown · Jun 24, 2002
Tires

WHILE TRAVELING ON HIGHWAY HEARD A NOISE. CONSUMER WAS ABLE TO PULL OVER TO THE SHOULDER ,AND RIGHT REAR TIRE TREAD SEPARATED. FIRESTONE , BRIDGESTONE, POTENZA. DEALERSHIP WAS AWARE OF PROBLEM.*AK

NHTSA ODI #8012514

Mileage unknown · Feb 20, 2001
TiresCrashInjury

TOYO ALL SEASON, PROXES, P215/55R16 DOT CXVD7A21000, ORIGINAL EQUIPMENT, $ 8000 DAMAGE TO VEHICLE, BLOWOUT ON RIGHT REAR TIRE DUE TO TREAD SEPARATION AT 65 MPH, ONE PERSON WAS INJURED IN ACCIDENT, CONSUMER LOST CONTROL STRIKING A BARRIER WALL. *AK *SLC

NHTSA ODI #880805

Official recalls

3

20V008000 · Air Bags:frontal:passenger Side:inflator Module

Jan 9, 2020

Nissan North America, Inc. (Nissan) is recalling certain 2001-2003 Maxima, 2002-2006 Sentra, 2002-2004 Pathfinder, 2007-2011 Versa Sedan and Versa Hatchback, 2001-2004 Infiniti I30 and I35, 2002-2003 Inifiniti QX4, 2003-2008 Infiniti FX35 and FX45 and 2006-2010 M35 and M45 vehicles. The vehicles are equipped with non-desiccated, frontal passenger air bag inflators containing phase stabilized ammonium nitrate (PSAN) propellant that were used as interim remedy parts for previous Takata recalls. These inflators may explode due to propellant degradation occurring after long-term exposure to high absolute humidity, high temperatures, and high temperature cycling.

Consequence & remedy

Consequence: An inflator explosion may result in sharp metal fragments striking the driver or other occupants resulting in serious injury or death.

Remedy: Nissan will notify owners, and dealers will replace the front passenger air bag inflators with alternate desiccated inflators, free of charge. The recall began February 12, 2020. Owners may contact Nissan customer service at 888-737-9511 or Infiniti customer service at 888-810-3715.

15V287000 · Air Bags

May 15, 2015

Nissan North America, Inc. (Nissan) is recalling certain model year 2001-2003 Nissan Maxima, 2002-2004 Pathfinder, 2002-2006 Sentra, 2002-2003 Infiniti QX4 and I35, 2003 FX35 and FX45, and 2001 I30 vehicles. Upon deployment of the passenger side frontal air bag, excessive internal pressure may cause the inflator to rupture.

Consequence & remedy

Consequence: In the event of a crash necessitating deployment of the passenger's frontal air bag, the inflator could rupture with metal fragments striking the vehicle occupants potentially resulting in serious injury or death.

Remedy: Nissan will notify owners, and dealers will replace the passenger air bag inflator, free of charge. The recall began on June 15, 2015. Owners may contact Nissan customer service at 1-800-647-7261. Note: On December 18, 2015 Nissan informed NHTSA of an amendment of this recall to remove 2004-2005 Infiniti FX35 and FX45 vehicles.

02V146000 · Suspension:front:control Arm:lower Arm

May 30, 2002

ON CERTAIN PASSENGER VEHICLES, THE PIN AT THE END OF THE FRONT SUSPENSION TRANSVERSE LINK (LOWER CONTROL ARM) COULD BREAK WHERE IT IS MOUNTED TO THE FRAME.

Consequence & remedy

Consequence: THIS CAN CAUSE A KNOCKING SOUND AND ABNORMAL STEERING. THIS COULD RESULT IN DIFFICULTY CONTROLLING THE VEHICLE AND INCREASING THE RISK OF A CRASH.

Remedy: DEALERS WILL REPLACE THE TRANSVERSE LINKS ON THE LEFT AND RIGHT SIDES WITH NEW ONES. OWNER NOTIFICATION BEGAN JULY 29, 2002. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT NISSAN AT 1-800-647-7261 OR INFINITI AT 1-800-662-6200.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

EA21002 · Desiccated Air Bag Inflator Rupture

Opened Sep 17, 2021 · No close date supplied

Status: open (inferred from source dates) · Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Additional source detail variants (2)

Air Bags:frontal:driver Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.